Dimensional data is subject to manufacturing tolerances and change without notice.
Pipe Size (in.) |
Approx. Weight (lbs.) |
Dome Open Area (sq. in.) |
2 - 4 | 26 | 103 |
5, 6 | 27 | 103 |
8 | 28 | 103 |
ENGINEERING SPECS: Zurn Z100-EA roof drain includes a dura-coated cast iron (DCCI) body with combination membrane flashing clamp / gravel guard, adjustable extension, secondary clamping collar with o-ring and low-silhouette poly-dome strainer.
Outlet Types
Outlet Type | Available Pipe Sizes (in.) |
Body Height Dimension (E) |
Inside Caulk (IC) | 2 - 6, 8 | 5 1/4 in. |
Threaded (IP) | 2 - 6, 8 | 3 3/4 in. |
No-Hub (NH) | 2 - 6, 8 | 5 1/4 in. |
Neo-Loc (NL) | 2 - 4 | 4 5/8 in. |
Dome Options
Poly-Dome* with DCCI Body (Z) |
6-3/4 In. High Aluminum Dome with DCCI Body (ZA) |
Cast Iron Dome with DCCI Body (ZC) |
Plain Bronze Dome with DCCI Body (ZRB) |
*Regularly furnished unless otherwise specified
Available Accessories
Angular Underdeck Clamp (-AC) | Roof Sump Receiver (-R) |
Acid Resistant Epoxy Coated Finish (-AR) | Secondary Clamping Collar (-SC) |
3/4 - 4 in. Adjustable Water Level Regulator (-AW) | Stainless Steel Mesh Screen Over Dome (-SS) |
Bronze Mesh Screen Over Dome (-BS) | Vandal-Proof Secured Top (-VP) |
Underdeck Clamp (-C) | 2-in. Internal Water Dam (-W2) |
Dex-o-Tex Flange (-DX) | 3-in. Internal Water Dam (-W3) |
Static Extension (1 - 4-in.; specify height) (-E) | 4-in. Internal Water Dam (-W4) |
Static Extension With Secondary Clamp Collar at Body (-ES) | Vertical Expansion Joint (See Z190) (-XJ) |
Flush Grate (-FG) | Stainless Steel Perforated Gravel Guard (-84) |
Galvanized Cast Iron (-G) | Stainless Steel Perforated Extension (-85) |
Galvanized Cast Iron Dome (ZC only) (-GD) | 2-in. High External Water Dam (-89) |
High Dome (-H) | 90° Threaded Side Outlet Body (-90) |