Zurn Z100-90 Roof Drain — Lateral Roof Drain

Dimensional data is subject to manufacturing tolerances and change without notice.

Download Specifications PDF

Zurn Z-100-90 roof drain

Pipe Size
(in.) (A)
Approx.
Weight (lbs.)
Dome Open
Area (sq. in.)
D (in.) M (in.)
2 37 103 5 1/2 4 1/4
3 35 103 5 1/2 3 11/16
4 36 103 5 1/2 3 3/16
5 45 103 5 7/8 4 13/16
6 45 103 5 7/8 4 1/4


ENGINEERING SPECS: Zurn Z100-90 roof drain includes a dura-coated cast iron (DCCI) body with combination membrane flashing clamp / gravel guard, perforated ring and low-silhouette poly-dome strainer.  


 

Outlet Types

Outlet Type Available Pipe
Sizes (in.)
Body Height
Dimension (E)
Threaded (IP) 2 - 4 5 1/4 in.
Threaded (IP) 5, 6 7 7/8 in.

 


 

Dome Options

Poly-Dome* with DCCI Body (Z)
6-3/4 In. High Aluminum Dome with DCCI Body (ZA)
Cast Iron Dome with DCCI Body (ZC)
Plain Bronze Dome with DCCI Body (ZRB)

*Regularly furnished unless otherwise specified

 


 

Available Accessories

Angular Underdeck Clamp (-AC) Roof Sump Receiver (-R)
Acid Resistant Epoxy Coated (-AR) Secondary Clamping Collar (-SC)
3/4 - 4 in. Adjustable Water Level Regulator (specify height; ZC only) (-AW) Stainless Steel Mesh Screen Over Dome (-SS)
Bronze Mesh Screen Over Dome (-BS) Vandal-Proof Secured Top (-VP)
Underdeck Clamp (-C) 2-in. Internal Water Dam (-W2)
Static Extension (1 - 4-in.; specify height) (-E) 3-in. Internal Water Dam (-W3)
Adjustable Extension Assembly (1 3/4 - 3 1/2 in.) (-EA) 4-in. Internal Water Dam (-W4)
Static Extension With Secondary Clamp at Collar Body (-ES) Vertical Expansion Joint (-XJ)
Flush Grate (Replaces Dome Strainer) (-FG) Stainless Steel Perforated Gravel Guard (-84)
Galvanized Cast Iron (-G) Stainless Steel Perforated Extension (-85)
Galvanized Cast Iron Dome (ZC only) (-GD) 2-in. High External Water Dam (-89)